leviton humidity sensor manual

The Leviton Humidity Sensor is a smart device that detects excess moisture in rooms, automatically activating ventilation fans to reduce condensation and mold growth, designed for bathrooms and other spaces to enhance air quality and comfort.

Overview of the Leviton Humidity Sensor and Fan Control

The Leviton Humidity Sensor and Fan Control is a cutting-edge device designed to automatically detect excess humidity in bathrooms and other spaces, activating the ventilation fan to reduce condensation and prevent mold growth. It features microprocessor control with digital sensing technology for accurate humidity detection and fan activation. The device includes adjustable sensitivity settings and a built-in countdown timer for manual operation, ensuring optimal performance. Compatible with various load types, including LED, CFL, and incandescent lighting, it enhances air quality and comfort while providing energy-efficient solutions for home ventilation needs.

Features and Benefits of the Leviton Humidity Sensor

The Leviton Humidity Sensor offers automatic humidity detection, activating fans to reduce condensation and mold growth, with adjustable sensitivity and compatibility with various load types for efficient ventilation control.

Microprocessor Control with Digital Sensing Technology

The Leviton Humidity Sensor utilizes advanced microprocessor control combined with digital sensing technology to accurately detect humidity levels in real-time. This innovative system ensures precise and reliable operation, automatically activating ventilation fans when excess moisture is detected. The microprocessor processes data from the sensor to optimize fan performance, reducing condensation and mold growth effectively. With digital sensing, the device offers enhanced accuracy and responsiveness, ensuring optimal indoor air quality and safety. This technology enables seamless integration with various load types, making it a versatile solution for bathrooms and other spaces.

Adjustable Sensitivity and Built-in Countdown Timer

The Leviton Humidity Sensor features adjustable sensitivity settings, allowing users to customize the device to their specific needs. This ensures that the sensor accurately detects humidity levels without false activations. Additionally, the built-in countdown timer provides manual operation flexibility, enabling the fan to run for a preset duration after being triggered. This dual functionality enhances user control, ensuring optimal ventilation and energy efficiency. The adjustable sensitivity and countdown timer work together to provide a tailored solution for maintaining a healthy indoor environment.

Compatibility with Various Load Types

The Leviton Humidity Sensor is designed to work with a wide range of load types, including incandescent, LED, CFL, and fluorescent lighting. It is also compatible with fans and other household devices, supporting up to 600W for incandescent/halogen loads and 400VA for magnetic low voltage applications. This versatility allows the sensor to integrate seamlessly into various electrical systems, providing reliable performance across different setups. The device can be installed with or without a neutral wire, further enhancing its adaptability for diverse installation requirements.

Installation Instructions for the Leviton Humidity Sensor

To install, turn off power at the circuit breaker, ensure wiring matches the configuration, and follow safety precautions to avoid fire or electrical hazards.

Step-by-Step Guide for Proper Installation

Turn off power at the circuit breaker before starting.
Verify wiring matches the configuration in the manual.
Mount the sensor in a location that detects steam effectively.
Connect wires carefully, ensuring correct load and line connections.
Set the wallplate and secure it firmly.
Restore power and test functionality to ensure proper operation.
Always follow safety guidelines and consult an electrician if unsure.

Important Safety Precautions

– Turn off power at the circuit breaker before installation.
– Avoid fire hazards by ensuring the device is not overloaded.
– Do not install to control a receptacle or exceed specified load ratings.
– Comply with electrical codes and regulations during installation.
– Consult an electrician if unsure about any step.
– Do not use in hazardous locations or where it could be exposed to water.
– Ensure proper grounding for safe operation.
– Keep the device clean and avoid using harsh chemicals.
– Do not attempt repairs without authorized guidance.
Always prioritize safety to prevent risks of shock, fire, or device malfunction.

Operating Modes of the Leviton Humidity Sensor

The Leviton sensor offers automatic and manual modes, ensuring optimal ventilation control. It detects humidity levels and activates fans automatically or allows manual override for user convenience.

Automatic Humidity Detection and Fan Activation

The Leviton Humidity Sensor automatically detects excess moisture in the air, activating the ventilation fan to reduce condensation and prevent mold growth. This feature ensures optimal air quality by maintaining a healthy humidity level. The sensor uses advanced digital technology to accurately monitor the environment and trigger the fan when humidity exceeds the set threshold. With adjustable sensitivity settings, users can customize the activation levels to suit their space. Additionally, the built-in countdown timer allows for continuous operation with preset time-outs, enhancing convenience and energy efficiency. This automatic mode provides a seamless solution for maintaining a comfortable and hygienic indoor environment.

Manual Operation Features

The Leviton Humidity Sensor offers manual operation for added flexibility. Users can press the push pad to activate the fan or light manually, overriding automatic settings temporarily. The countdown timer feature allows manual operation with a preset duration, ensuring the fan runs for a specified time before turning off. Additionally, the sensor’s LED indicator provides visual feedback, illuminating steadily during manual operation. This feature is ideal for situations where immediate ventilation is needed, offering a convenient override option while maintaining the device’s energy-efficient automatic functionality.

Adjusting Settings on the Leviton Humidity Sensor

The Leviton Humidity Sensor allows users to adjust sensitivity and timeout duration, ensuring customized performance and optimal ventilation control in various environments.

Sensitivity Adjustment for Optimal Performance

The Leviton Humidity Sensor offers adjustable sensitivity to customize its response to moisture levels. Users can reduce sensitivity to minimize false activations or increase it for higher humidity detection. This feature ensures the sensor accurately triggers the fan based on specific room conditions. Adjustments are made using a small screwdriver, allowing precise control over the sensor’s performance. Proper sensitivity calibration ensures efficient ventilation and prevents unnecessary fan operation, optimizing energy use and maintaining comfort. This feature is particularly useful in varying room sizes and humidity levels.

Setting the Timeout Duration

The Leviton Humidity Sensor allows users to set a timeout duration, determining how long the fan runs after activation. This feature ensures the fan operates efficiently, reducing moisture without unnecessary runtime. The timeout can be adjusted using a dial or selector, providing flexibility for different room sizes and humidity levels. Properly setting the timeout duration helps maintain optimal ventilation while saving energy. This feature is especially useful for manual operation, giving users control over how long the fan runs after detecting excess humidity.

Troubleshooting Common Issues

Common issues with the Leviton Humidity Sensor may include sensor inactivity or improper fan activation. Check power connections, adjust sensitivity settings, and ensure proper installation for optimal performance.

Resolving Common Problems with the Humidity Sensor

Common issues with the Leviton Humidity Sensor often relate to sensor responsiveness or fan operation. Ensure the device is properly powered and wires are securely connected. If the sensor is not activating the fan, check the sensitivity settings and adjust them using the provided dials. For manual operation, press the push pad to test functionality. Additionally, verify that the sensor is installed in an optimal location, away from direct drafts or heaters, to ensure accurate humidity detection and reliable performance. Regular cleaning with a damp cloth can also maintain sensor accuracy and prevent malfunction.

Compliance and Warranty Information

The Leviton Humidity Sensor adheres to cULus standards and is compliant with UL 873 and C22.2 No. 0, ensuring safety and reliability. It is backed by a comprehensive warranty, with specific terms outlined in the product manual, and offers dedicated technical support for any inquiries or issues.

Agency Standards and Compliance

The Leviton Humidity Sensor and Fan Control comply with cULus certification, meeting UL 873 and C22.2 No. 0 standards for safety and performance. Designed to adhere to electrical codes, it supports energy-efficient practices and is compatible with 2019 and 2022 California Title 24 requirements. This ensures the device operates safely and efficiently while meeting regulatory demands for indoor air quality and energy conservation. Compliance with these standards guarantees reliable performance and adherence to industry safety protocols.

Warranty Details and Technical Support

The Leviton Humidity Sensor and Fan Control is backed by a limited warranty, ensuring coverage for defects in materials and workmanship. For technical assistance, customers can contact Leviton’s support team at 1-800-824-3005. Additional resources, including user manuals and troubleshooting guides, are available on Leviton’s official website. For Canadian residents, warranty inquiries should be directed to Leviton Manufacturing of Canada Ltd. This comprehensive support ensures optimal performance and addresses any operational concerns effectively.